Search results for "platform switch"
showing 10 items of 13 documents
Implant Abutment Cleaning by Plasma of Argon: 5-Year Follow-Up of a Randomized Controlled Trial.
2015
Contamination of implant abutments could potentially influence the peri-implant tissue inflammatory response. The aim of the present study is to assess the radiographic bone changes around customized, platform-switched abutments placed according to the "one-abutment-one-time" protocol, with and without plasma of argon cleaning treatment.Thirty healthy patients with thin gingival biotype (1 mm) and history of periodontal disease received one maxillary implant each. Immediately before abutment connection, patients were randomly assigned to control group (cleaning protocol by steaming) or test group (plasma of argon treatment). Outcome measures were: 1) success rate of implants and prostheses;…
Radiographic evaluation of conical tapered platform‐switched implants in the posterior mandible: 1‐year results of a two‐center prospective study
2015
Abstract Objective Long‐term success of dental implants depends on healthy peri‐implant soft tissues and adequate bone levels. This prospective study aims to assess bone level changes around implants with internal conical connection and platform‐switching abutments in the posterior mandible. Material and methods Adult patients missing at least two teeth in the posterior mandible and with a natural tooth mesial to the implant site received two or three adjacent internal conical connection implants. After a minimum transmucosal healing period of 8 weeks, single crown restorations were cemented over platform‐switching abutments. Changes in marginal bone levels were measured in standardized per…
Marginal soft tissue stability around conical abutments inserted with the one abutment-one time protocol after 5 years of prosthetic loading
2018
BACKGROUND Soft tissue stability is crucial to obtain and maintain optimal esthetic results. PURPOSE This study aimed to investigate, over 5 years, the soft tissue response using a conical abutment together with the "one-abutment one-time" (OA-OT) protocol in the restoration of implants inserted in the anterior esthetic area. MATERIAL AND METHODS From January 2011 to January 2012, all consecutive patients requiring an implant n the maxillary area between canines were enrolled. After submerged healing and osseointegration, a definitive abutment with a provisional crown was inserted. After 1 month, the definitive crown was delivered (Tdef). Analog impressions were taken before tooth extractio…
Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial
2019
Abstract Aim To compare the clinical performance and marginal bone levels of implants restored with platform‐switching (PS) or platform‐matching (PM) abutments. Materials and Methods Adult patients missing two or more adjacent teeth in the posterior mandible received 2–4 CAMLOG SCREW‐LINE implants and were randomly allocated to the PM or PS group, receiving the corresponding prosthetic components from surgery onwards. Implants were conventionally loaded with single cemented crowns. Patients were followed annually for 5 years. Outcome measures were marginal bone level changes, implant survival, performance of the prosthetic components and clinical parameters plaque index, sulcus bleeding ind…
Clinical and radiographic performance of self‐locking conical connection implants in the posterior mandible: Five‐year results of a two‐centre prospe…
2021
Abstract Objective This prospective study aims to assess the 5‐year clinical performance of implants with internal conical connection and platform‐switched abutments in the posterior mandible. Material and Methods Healthy adults missing at least two teeth in the posterior mandible and with a natural tooth mesial to the implant site received two or three adjacent implants. After a transmucosal healing period single crown restorations were cemented on platform‐switched abutments. Changes in marginal bone levels were investigated in standardized periapical radiographs from surgery and loading (baseline) to 60‐months post‐loading. Results Twenty‐four patients received 52 implants. Bone remodell…
The influence of platform switching in dental implants. A literature review.
2010
Introduction: The platform switching concept involves the reduction of the restoration abutment diameter with respect to the diameter of the dental implant. In 1991, dental implants of 5 and 6 mm diameter platforms were introduced. However, matching-diameter prosthetic abutments were not available. These implants were restored with “standard”-diameter prosthetic components (4,1 mm). Long-term follow up around these wide-platforms showed higher levels of bone preservation. In time, it has been called platform switching. The first case report applying this concept was indexed in MedLine in 2005. Materials and Methods: The aim of this article is to carry out a literature review of articles whi…
The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
2011
Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…
Effect of platform switching on the peri-implant bone: A finite element study
2015
Background: There exists a relation between the presence and location of the micro-gap and the loss of peri-implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. Material and Methods: A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled.…
Platform switch versus platform match in the posterior mandible – 1-year results of a multicentre randomized clinical trial.
2014
Objective The purpose of this ongoing randomized study was to assess differences in bone level changes and success rates using implants supporting single crowns in the posterior mandible either with platform matched or platform switched abutments. Material and Methods Patients aged 18 and above, missing at least two teeth in the posterior mandible and with a natural tooth mesial to the most proximal implant site were enrolled. Randomization followed implant placement. Definitive restorations were placed after a minimum transgingival healing period of 8 weeks. Changes in crestal bone level from surgery and loading (baseline) to 12-month post-loading were radiographically measured. Implant su…
Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…
2016
Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…